![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 52](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370052.webp)
!
3-4
Section
Wiring
39
Caution
Use either the 24--V origin input signal or the 5--V origin input signal, but not both.
Also, be sure not to connect them to the wrong terminal. Using both signals or
connecting them to the wrong terminal will result in damage to internal circuitry.
Origin Input Signal (24 V)
Example:
OMRON E2R-A01 Proximity
Sensor (NPN output type)
Position Control Unit
24-VDC power
supply
150
Ω
4.7 k
Ω
680
Ω
+v
0 V
+
--
Signal
Switch
circuitry
A15/B15
A14/B14
Origin Input Signal (5 V) (Line Driver Input)
Position Control Unit
OMRON R88D-WT
Servo Motor Drive
20
4.7 k
Ω
150
Ω
680
Ω
A16/B16
A14/B14
19
+z
--z
The positioning completed input signal is also used as an origin search com-
pleted signal in modes 2 and 3. Adjust the setting of the servo motor drive so that
this signal always turns off while the servo motor is operating, and on when the
motor is stopped.
An origin search operation cannot be completed unless the positioning com-
pleted input signal turns ON after positioning has been completed.
Position Control Unit
24-VDC
power supply
4.7 k
Ω
(1/2W)
680
Ω
A12/B12
+
OMRON R88D-WT
Servo Motor Drive
--
26
25
INP
A1/B1
--INP
Positioning Completed
Input Signal
Summary of Contents for CS1W-NC113 - REV 02-2008
Page 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Page 2: ...iv ...
Page 4: ...vi ...