1-5
Section
Specifications
10
1-5-2 Performance Specifications
Item
Model
CS1W-NC113/133
CS1W-NC213/233
CS1W-NC413/433
Applicable PC models
CS1-series PCs
I/O requirements
Words
5 words
10 words
20 words
/
q
Slots
1 slot
Controlled driver
Pulse-train input-type servo motor drive or stepping motor drive
NC113/213/413 models have open collector output.
NC133/233/433 models have line driver output.
Control
Control system
Open-loop control by pulse train output
Number of control
axes
1 axis
2 axes
4 axes
Control unit
Pulse
Positioning operations
Two types: memory operation and direct operation
Independent
1 axis
2 independent axes
4 independent axes
Linear interpolation
None
2 axes max.
4 axes max.
Speed control
1 axis
2 independent axes
4 independent axes
Interrupt feeding
1 axis
2 independent axes
4 independent axes
Positions
Range
--1,073,741,823 to 1,073,741,823 pulses (See note.)
Data items
100/axis
Speeds
Range
1 pps to 500 Kpps
p
Data items
100/axis
Acceleration and
d
l
i
i
Range
0 to 250 s, until maximum speed is reached.
deceleration times
Data items
9/axis for acceleration and deceleration each
Functions and
settings
Origin search
Origin proximity input signal: selectable (absent, N.O. or N.C. contact).
Origin input signal: selectable (N.O. or N.C. contact)
Origin compensation: --1,073,741,823 to 1,073,741,823 pulses
Origin search speed: High-speed or proximity-speed can be set.
Origin detection method: May be set to stop upon origin input signal
after proximity input signal has turned ON, to stop upon origin input
signal after proximity input signal has turned OFF, to stop upon origin
input signal without using proximity input signal, or to stop upon origin
input signal after limit input signal has turned OFF.
N.O. = Normally open
N.C. = Normally closed
Jogging
Jogging can be executed at a specified speed.
Dwell times
19/axis can be set from 0 to 9.99 s (unit: 0.01 s).
Acceleration/
deceleration curves
Trapezoidal or S-curve (Can be set separately for each axis.)
Zones
Zone Flag turns ON when present position is within a specified zone.
Three zones can be set for each axis.
Software limits
Can be set within a range of --1,073,741,823 to 1,073,741,823 pulses.
Backlash
compensation
0 to 9,999 pulses. Compensation speed can also be set.
Teaching
With a command from the PC, the present position can be taken as the
position data.
Deceleration stop
The STOP command causes positioning to decelerate to a stop
according to the specified deceleration time.
Emergency stop
Pulse outputs are stopped by an external emergency stop command.
Functions and
settings
Present position
preset
The PRESENT POSITION PRESET command can be used to change
the present position to a specified value.
se
gs
Override
When the override enabling command is executed during positioning,
the target speed is changed by applying the override coefficient.
Possible to set to a value from 1 to 999% (by an increment of 1%)