3-2
Section
Installation
24
3-2-3 Precautions When Handling the PCU
•
Before installing or disconnecting the PCU or connecting cable, be sure to first
turn off both the Programmable Controller and the power supply.
•
To minimize any influence from noise, place I/O wiring, high-voltage lines, and
power lines in separate ducts.
•
Wire clippings tend to get scattered around during wiring, so leave the label in
place on top of the PCU to prevent any clippings from getting inside the PCU.
Once the wiring has been completed, be sure to remove the label to provide
ventilation.
Remove the label after
completing the wiring.
3-2-4 Dimensions
CS1W-NC113/NC133/NC213/NC233/NC413/NC433
Note
The above diagram is for the CS1W-NC413.