![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 192](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370192.webp)
8-4
Section
Positioning Sequences
182
Code
Name
Description
Operation
0
Terminating
The sequence is executed, and
then positioning is stopped until
START is executed for the next
sequence.
Target speed
Deceleration
Stopped at
initial speed
Acceleration
Initial
speed
Time
START
Target position
1
Automatic
The sequence is executed, and
then positioning is paused for the
duration of the dwell time before the
next sequence is started
automatically.
Target speed
Next sequence started
Time
START
Dwell time
2
Continuous
The sequence is executed, and
then positioning continues with the
next sequence without stopping at
the target position. (If a dwell time is
set, however, then positioning will
pause for the duration of the dwell
time.)
Target speed
Target position passed without
stopping.
Time
START
Target speed for
next sequence
3
Bank end
Positioning is stopped after
completion. When START is next
executed, positioning starts again
with the designated sequence when
the Sequence Number Enable Bit
turns ON.
Target speed
Time
START
Positioning stopped
4
Speed control
Pulse output is maintained at the
speed set for the sequence. The
present position is calculated even
during continuous output. The
direction of the pulse output is
determined by the “sign” set for the
position data. To stop this pulse
output, use the STOP command.
Target speed
Time
START
Positioning
stopped
STOP
Note
The initial speed is used at the end.
Summary of Contents for CS1W-NC113 - REV 02-2008
Page 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Page 2: ...iv ...
Page 4: ...vi ...