![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 106](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370106.webp)
4-7
Section
Zone Data Area
93
Address
Name
Configuration/Explanation
Default
i
g
/
p
setting
NC1
j
3
NC2
j
3
NC4
j
3
X axis
Y axis
Z axis
U axis
12F8
12F9
22F8
22F9
32F8
32F9
42F8
42F9
Zone #0, CCW side
(rightmost word)
Zone #0, CCW side
(leftmost word)
(2 words)
CCW
side
15
00 15
00
Zone #0, CCW side
(leftmost word)
Zone #0, CCW side
(rightmost word)
CW
side
15
00 15
00
Zone #0, CW side
(leftmost word)
Zone #0, CW side
(rightmost word)
Sets the CCW/CW side values for zone #0 (in
0000
0000
12FA
12FB
22FA
22FB
32FA
32FB
42FA
42FB
Zone #0, CW side
(rightmost word)
Zone #0, CW side
(leftmost word)
(2 words)
Sets the CCW/CW-side values for zone #0 (in
pulse units). The values can be set in the
range --1,073,741,823 to 1,073,741,823
pulses as signed 32-bit hexadecimal data
using 2 words.
Setting range: C0000001 to 3FFFFFFF Hex
(--1,073,741,823 to 1,073,741,823)
12FC
12FD
22FC
22FD
32FC
32FD
42FC
42FD
Zone #1, CCW side
(rightmost word)
Zone #1, CCW side
(leftmost word)
The settings are the same as for zone #0.
12FE
12FF
12FE
22FF
32FE
32FF
42FE
42FF
Zone #1, CW side
(rightmost word)
Zone #1, CW side
(leftmost word)
1300
1301
2300
2301
3300
3301
4300
4301
Zone #2, CCW side
(rightmost word)
Zone #2, CCW side
(leftmost word)
The settings are the same as for zone #0.
1302
1303
2302
2303
3302
3303
4302
4303
Zone #2, CW side
(rightmost word)
Zone #2, CW side
(leftmost word)