1-3
Section
Basic Operations
6
different positions while positioning is being performed. Linear interpolation,
however, is not possible during direct operation.
Speed
Start
Speed changed
Time
New target position
Target position before
position changed
Position changed
Start
With memory operation, positioning sequences (i.e., individual positioning
operations, which include data such as positions and speeds) are transferred to
the PCU in advance, and then positioning is executed from the CPU Unit by
specifying those positioning sequences by number. Depending on the comple-
tion code that is set, positioning sequences can be executed using independent
positioning, automatic positioning, or continuous positioning. In the following
illustrations, “#0” “#1” “#2” and “#3” indicate positioning sequence numbers.
Speed
“#0”
“#1”
“#2”
“#3”
Independent
Positioning
Automatic
Positioning
Continuous
Positioning
Positioning Sequences Executed in Order
Start
Stop Start
Pauses for length
of dwell time that
is set.
Does not stop.
Time
When an interrupt input signal is received, positioning is continued for the speci-
fied amount of pulses and then stopped.
Time
Interrupt input signal
Specified amount
of pulses
Speed
Memory Operation
Interrupt Feeding