9-7
Section
Error Counter Reset Output and Origin Adjustment Command Output
224
•
Beginning word of the operating data area, l, is specified in m and m+1.
Set the beginning words of the operating data area and designate the axis
parameters used with the common parameters as shown below.
Word
Name
Bit
Reference
m
Operating data
area designation
00 to 15
Section 4
m+1
Beginning word of
operating data
area
00 to 15
m+2
Axis parameter
designation
00 to 15
9-7-3 Operating Memory Area Allocation and External I/O Connector Pin
Arrangement
Operating Memory Area
Name
Model
Operating memory area
Bit
Details
X
axis
Y
axis
Z
axis
U
axis
Error counter
reset output
and origin
adjustment
command
output
NC4
j
3
NC2
j
3
NC1
j
3
n
n
n
n+2
n+2
n+4
n+6
13
1: ON; 0: OFF
Busy Flag
NC4
j
3
NC2
j
3
NC1
j
3
n+8
n+4
n+2
n+11
n+7
n+14
n+17
13
1: Busy
Pin number
Name
A10 (X/Z axis)/B10 (Y/U axis) Error counter reset output or origin adjustment
command output (24 v)
A11 (X/Z axis)/B11 (Y/U axis)
Error counter reset output or origin adjustment
command output (5 v)
9-7-4 Timing Chart
In the following timing chart, operation modes 0 to 2 are used, with the X axis for
a 4-axis PCU taken as an example.
Example 1: Used as general outputs in mode 0
Error counter reset output or
origin adjustment command
output (word n, bit 13)
Error counter reset output or
origin adjustment command
output (PCU output signal)
(A10/A11 on X axis)