6-5
Section
Origin Search Timing Charts
150
6-5-4 Emergency Stop of Origin Search
The origin search will be interrupted if the emergency stop input signal
(A20/B20) is input while the origin search is being executed. To execute the ori-
gin search again, first release the pulse output prohibition.
The following diagram shows an example of an emergency stop during an origin
search when there is an origin proximity input signal reversal.
Pulse output
Time
Origin proximity
input signal
Origin input
signal
ORIGIN
SEARCH
RELEASE
PROHIBIT/
ERROR RESET
Emergency
stop input
Error Flag
Positioning
Completed
Flag
Busy Flag
Deceleration
Stop Execution
Flag
No Origin Flag
Origin Stop Flag
Error counter
reset output
Start
Stop
Start