![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 263](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370263.webp)
10-3
Section
Direct Operation
253
DM Area
D00508 through D00539 are used in this program example, and the following
positions are set in this area.
DM
Setting
Contents of setting
DM
Setting
Contents of setting
D00508
05DC
Position: 1,500 pulses
( DC H )
D00524
1194
Position: 4,500 pulses
(119 H )
D00509
0000
,
p
(5DC Hex)
D00525
0000
,
p
(1194 Hex)
D00510
012C
Speed: 300 pps (12C Hex)
D00526
01F4
Speed: 500 pps (1F4 Hex)
D00511
0000
p
pp (
)
D00527
0000
p
pp (
)
D00512
0005
Acceleration time: 5 ms
( H )
D00528
0005
Acceleration time: 5 ms
( H )
D00513
0000
(5 Hex)
D00529
0000
(5 Hex)
D00514
0005
Deceleration time: 5 ms
( H )
D00530
0005
Deceleration time: 5 ms
( H )
D00515
0000
(5 Hex)
D00531
0000
(5 Hex)
D00516
0BB8
Position: 3,000 pulses
(BB8 H )
D00532
0000
Position: 0 pulses (0 Hex)
D00517
0000
,
p
(BB8 Hex)
D00533
0000
p
(
)
D00518
0190
Speed: 400 pps (190 Hex)
D00534
0190
Speed: 400 pps (190 Hex)
D00519
0000
p
pp (
)
D00535
0000
p
pp (
)
D00520
0005
Acceleration time: 5 ms
( H )
D00536
0014
Acceleration time: 20 ms
(1 H )
D00521
0000
(5 Hex)
D00537
0000
(14 Hex)
D00522
0005
Deceleration time: 5 ms
( H )
D00538
0014
Deceleration time: 20 ms
(1 H )
D00523
0000
(5 Hex)
D00539
0000
(14 Hex)