10-5
Section
Origin Search
264
Data Memory Settings
DM
Setting
Contents of setting
DM
Setting
Contents of setting
D20000
000D
Sets the operating data area
to D00500 (1F4 Hex)
D20016
0000
Backlash compensation
(default setting)
D20001
01F4
o 00500 (
e )
onwards.
D20017
0000
Backlash compensation
d (d f l
i )
D20002
0001
Specifies that the axis
parameters in the area
starting from D20004 will be
used for all axes.
D20018
0000
p
speed (default setting)
D20003
0000
Reserved
D20019
0000
Acceleration/Deceleration
curve: trapezoid (default
setting)
D20004
0060
I/O settings (default setting)
D20020
0005
Origin search acceleration
i
(0
i
d)
D20005
0321
CW limit input
used/single-direction
mode/mode 1
D20021
0000
g
time (0 to maximum speed):
5 ms (5 Hex)
D20006
01F4
Maximum speed: 500 pps
(1F4 Hex)
D20022
0005
Origin search deceleration
time (maximum speed to 0):
D20007
0000
(1F4 Hex)
D20023
0000
time (maximum speed to 0):
5 ms (5 Hex)
D20008
0000
Initial speed (default setting) D20024
270F
Positioning monitor time
(default setting)
D20009
0000
D20025
0001
CCW software limit (default
i )
D20010
01F4
Origin search high speed:
00
(1F H )
D20026
C000
(
setting)
D20011
0000
g
g
p
500 pps (1F4 Hex)
D20027
FFFF
CW software limit (default
i )
D20012
0064
Origin search proximity
d 100
(6 H )
D20028
3FFF
(
setting)
D20013
0000
g
p
y
speed: 100 pps (64 Hex)
D20029
0000
Reserved
D20014
0000
Origin compensation (default
i )
D20030
0000
Reserved
D20015
0000
g
p
(
setting)
D20031
0000
Initial pulse designation
(default setting)
Designation of the Operating Data Area
The operating data area is allocated to D00500 through D00523 by the data
memory settings. No prior settings are needed for the operating data area
because data is set during programming.
Data Settings
The values for D20004 onwards are transferred when the power is turned ON (or
at restart).
This data area is not used for origin search. It should be left entirely at the default
settings (0).
This data area is not used for origin search. It should be left entirely at the default
settings (0).
This data area is not used for origin search. It should be left entirely at the default
settings (0).
This data area is not used for origin search. It should be left entirely at the default
settings (0).
Dwell times are not used for origin search, so this data area needs to be set com-
pletely to the default settings (0).
Zones are not used for origin search, so this data area needs to be set com-
pletely to the default settings (0).
Axis Parameters
Positioning Sequences
Speeds
Positions
Acceleration and
Deceleration Times
Dwell Times
Zones