![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 189](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370189.webp)
8-4
Section
Positioning Sequences
179
8-4-1 Sequence Format
Each positioning sequence is configured of three words, as shown below. Up to
100 of these sequences can be set for each axis, and transferred to the PCU and
saved.
15
00
Axis designation
Output code
Position designation
Completion code
12 11
08 07
04 03
Dwell time number
Accel. time number
Decel. time number
Initial speed number
Target speed number
The data that is used when performing memory operation using positioning
sequences is as follows.
One Axis Operation
•
The data (dwell time, acceleration time, deceleration time, initial speed, target
speed) for the starting axis (the axes from which memory operation is started)
is used.
•
The acceleration/deceleration curve set for the axis specified by the axis des-
ignation will be used.
•
The position set for the axis specified by the axis designation will be used.
•
The initial pulse designation for the axis specified by the axis designation will
be used.
Operation for Two Axes or More
•
The data (dwell time, acceleration time, deceleration time, initial speed, target
speed) for the starting axis is used.
•
Out of the acceleration/deceleration curves set for the axes specified by the
axis designation, the curve for the axis with the highest priority will be used.
The X axis has the highest priority and the U axis has the lowest.
•
The positions set for the axes specified by the axis designation will be used.
•
Out of the initial pulse designations for the axes specified by the axis designa-
tion, the slowest will be used.
The data that is used in 1-axis operation and 2-axis operation is shown in the
following table.