![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 71](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370071.webp)
4-1
Section
Overall Structure
58
4-1-1 Data Areas
The following tables give the addresses (bit/word addresses in the CPU Unit and
addresses in the PCU’s internal memory) for the parameters and data handled
by the PCU. For more details, refer to the relevant sections.
Common Parameter Area (refer to page 61)
Beginning word of common parameter area, m = 100
×
unit number.
Word (same for all models)
Name
Data size
m
Operating data area designation
1 word
m+1
Beginning word of operating data area
1 word
m+2
Axis parameter designation
1 word
m+3
Not used
1 word
Axis Parameter Area (refer to page 65)
Word (address in PCU)
Name
Data size
X axis
Y axis
Z axis
U axis
m+4 (0004)
m+32 (0020)
m+60 (003C)
m+88 (0058)
I/O settings
1 word
m+5 (0005)
m+33 (0021)
m+61 (003D)
m+89 (0059)
Operation mode selection
1 word
m+6 (0006)
m+34 (0022)
m+62 (003E)
m+90 (005A)
Maximum speed
2 words
m+8 (0008)
m+36 (0024)
m+64 (0040)
m+92 (005C)
Initial speed
2 words
m+10 (000A)
m+38 (0026)
m+66 (0042)
m+94 (005E)
Origin search high speed
2 words
m+12 (000C)
m+40 (0028)
m+68 (0044)
m+96 (0060)
Origin search proximity speed
2 words
m+14 (000E)
m+42 (002A)
m+70 (0046)
m+98 (0062)
Origin compensation
2 words
m+16 (0010)
m+44 (002C)
m+72 (0048)
m+100 (0064) Backlash compensation
1 word
m+17 (0011)
m+45 (002D)
m+73 (0049)
m+101 (0065) Backlash compensation speed
2 words
m+19 (0013)
m+47 (002F)
m+75 (004B)
m+103 (0067) Acceleration/Deceleration curves
1 word
m+20 (0014)
m+48 (0030)
m+76 (004C)
m+104 (0068) Origin search acceleration time
2 words
m+22 (0016)
m+50 (0032)
m+78 (004E)
m+106 (006A) Origin search deceleration time
2 words
m+24 (0018)
m+52 (0034)
m+80 (0050)
m+108 (006C) Positioning monitor time
2 words
m+25 (0019)
m+53 (0035)
m+81 (0051)
m+109 (006D) CCW software limit
2 words
m+27 (001B)
m+55 (0037)
m+83 (0053)
m+111 (006F) CW software limit
2 words
m+31 (001F)
m+59 (003B)
m+87 (0057)
m+115 (0073) Initial pulse designation
1 word
Summary of Contents for CS1W-NC113 - REV 02-2008