4-3
Section
Axis Parameter Area
71
4-3-3 Operation Modes
The four operation modes are described below. The following abbreviations are
used in the wiring diagrams:
DCRI: Error counter reset input
DCRO: Error counter reset output
IC:
Input common
OACI: Origin adjustment command input
OACO: Origin adjustment command output
OPI:
Origin proximity input
OS:
Origin input signal
PCSI: Positioning completed signal input
PCSO: Positioning completed signal output
PCU:
Position Control Unit
SMD: Stepping motor driver
Set mode 0 when using a stepping motor drive. A sensor is connected to the ori-
gin input signal (connector pin numbers A14/A15 and B14/B15). The response
time for the origin input signal is 0.1 ms. (N.O. contact setting)
OS
OPI
X axis
PCU
Pulses
SMD
24 VDC
IC
Set mode 1 when using a servo motor drive and connecting a line driver input
and a error counter reset output without using a positioning completed signal.
The response time for the origin line driver input is 0.1 ms. (N.O. contact setting)
IC
X axis
PCU
Pulses
24 VDC
OPI
OS
DCRO
Serv
motor
drive
Z-phase
output
DCRI
Mode 0
Mode 1