![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 232](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370232.webp)
9-6
Section
Override
222
9-6-4 Timing Chart
In the following timing chart, the target speed is changed by the override while
jogging the X axis for a 4-axis PCU.
Pulse output
Speed
Time
Positioning Completed
Flag (word n+8, bit 05)
Busy Flag
(word n+8, bit 13)
Speed
(I+10, I+11)
Override
(I+17)
Override enable
(word n, bit 14)
JOG
(word n, bit 09)
3E8 Hex (1000)
32 Hex (50)
64 Hex (100)
96 Hex (150)