![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 74](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370074.webp)
4-2
Section
Common Parameter Area
61
Memory Operation Data (refer to page 89)
PCU internal address
Name
Data size
X axis
Y axis
Z axis
U axis
1000
2000
3000
4000
Positioning
sequence
numbers 0 to 99
3 words
112C
212C
312C
412C
Speed numbers 0
to 99
2 words
11F4
21F4
31F4
41F4
Position numbers
0 to 99
2 words
12BE
22BE
32BE
42BE
Acceleration time
numbers 1 to 9
2 words
12D2
22D2
32D2
42D2
Deceleration time
numbers 1 to 9
2 words
12E5
22E5
32E5
42E5
Dwell time
numbers 1 to 19
1 word
Zone Data Area (refer to page 92)
PCU internal address
Name
Data size
X axis
Y axis
Z axis
U axis
12F8
22F8
32F8
42F8
Zone 0, CCW
2 words
12FA
22FA
32FA
42FA
Zone 0, CW
2 words
12FC
22FC
32FC
42FC
Zone 1, CCW
2 words
12FE
22FE
32FE
42FE
Zone 1, CW
2 words
1300
2300
3300
4300
Zone 2, CCW
2 words
1302
2302
3302
4302
Zone 2, CW
2 words
4-2
Common Parameter Area
The common parameter settings determine the areas used to set the operating
data (the operating data area) and axis parameters (the axis parameter area)
required for axis control. The common parameters must be set before using the
PCU.