![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 36](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370036.webp)
3-2
Section
Installation
23
3-2-2 Mounting the Unit
Follow the procedure outlined below to mount the Position Control Unit.
1, 2, 3...
1. Hook the top of the PCU into the slot in the Backplane.
Hook
Backplane
2. Carefully insert the PCU into the connector on the Backplane.
3. Tighten the screw on the bottom with a Philips-head screwdriver. Provide
enough space around the PCU to enable easy mounting and dismounting,
and to ensure good ventilation as shown below.
Duct
PCU
Duct
Philips-head screwdriver
20 mm min.
Backplane
20 mm min.
Note
Tighten the screw at the bottom of the PCU to a torque of 0.4 N
⋅
m.
4. To remove the PCU, use a Philips-head screwdriver to loosen the screw at
the bottom of the PCU, and rotate the PCU upwards before dismounting.
Summary of Contents for CS1W-NC113 - REV 02-2008
Page 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Page 2: ...iv ...
Page 4: ...vi ...