11-6
Section
Releasing Pulse Output Prohibition and Resetting After Errors
304
Cause
Error code
Clearing method
Emergency stop input
signal is ON
6000
After turning OFF the
emergency stop signal,
pulse output is enabled
with the rising edge of the
RELEASE
PROHIBIT/ERROR
RESET Bit.
If the RELEASE
PROHIBIT/ERROR
RESET Bit is turned ON
with the emergency stop
signal still ON, pulse
output will not be enabled.
CW limit input signal is ON 6100
Pulse output is enabled
with the rising edge of the
RELEASE
PROHIBIT/ERROR
RESET Bit.
Pulse output is only
ibl i th
it
CCW limit input signal is
ON
6101
p
y
possible in the opposite
direction to the limit input
signal that turned ON. For
example, if the CCW limit
input signal turned ON,
pulse output is only
possible in the CCW
direction.
Software limit error
5030
5031
5070
5071
Pulse output is enabled
with the rising edge of the
RELEASE
PROHIBIT/ERROR
RESET Bit.
Pulse output is only
possible in the opposite
direction to the software
limit that was reached. For
example, if the CW
software limit was
reached, pulse output is
only possible in the CCW
direction.
Note
1. It is possible to set with parameters whether the origin determination is
released or not when the emergency stop input signal or a CW/CCW limit
input signal turns ON.
2. If the origin determination is set to be released, the No Origin Flag will turn
ON when one of the above input signals is turned ON.
11-6-2 Beginning Words of Operating Memory Area, Operating Data Area,
and Parameter Areas
The beginning words of the operating memory area, operating data area, and
common parameter area used for a Position Control Unit (PCU) are determined
(or set) according to the following.
•
Beginning word of the operating memory area, n = CIO 2000 + 10
×
unit num-
ber
•
Beginning word of the common parameter area, m = 100
×
unit num-
ber
•
Beginning word of the operating data area, l, is specified in m and m+1.
Set the beginning words of the operating data area and designate the axis
parameters used with the common parameters as shown below.
Summary of Contents for CS1W-NC113 - REV 02-2008
Page 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Page 2: ...iv ...
Page 4: ...vi ...