![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 50](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370050.webp)
!
!
3-4
Section
Wiring
37
Caution
Be sure to wire the 5-VDC pulse output power supply with the correct polarity.
Wiring with the polarity reversed will result in damage to internal elements.
There is approximately 20 ms of output when origin search is completed in
modes 1 or 2.
Position Control Unit
24-VDC
power
supply for
output
5-VDC
power
supply
24-VDC
power
supply
+
--
OMRON R88D-WT
Servo Motor Drive
24-VDC
power
supply
1.6 k
Ω
OMRON R88D-WT
Servo Motor Drive
--ECRST
15
14
15
14
+
--
+
--
A1/B1
A10/B10
A2/B2
A1/B1
A11/B11
A2/B2
Position Control Unit
24-VDC
power
supply for
output
+ECRST
--ECRST
+ECRST
3-4-2 Connecting Input Signals
Caution
If the switching capacity is too low it may cause damage to the switch. Connect a
switch with a switching capacity of at least 5 mA for each input.
With N.C. inputs, be sure to connect a power supply for unused terminals and
turn them on.
This section shows examples of connecting interrupt, emergency stop, and CW/
CCW limit input signals.
The input section has both N.O. and N.C. inputs. Either can be used depending
on the axis parameter settings. For details regarding axis parameters, refer to
4-3 Axis Parameter Area
.
Depending on the setting of the origin search operation pattern, the point at
which the origin proximity signal or the CW/CCW limit signal changes from ON to
OFF is used as the timing for origin signal detection. In this case, use a sensor
with no chattering, such as a photoelectric sensor, for the input. Using a switch
with contacts may cause the position of the origin to be displaced due to chatter-
ing. For details on setting operation patterns for origin searches, refer to 132.
Error Counter Reset