![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 90](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370090.webp)
4-3
Section
Axis Parameter Area
77
Word
(PCU internal address)
Name
Enable timing
NC1
j
3
NC2
j
3
NC4
j
3
X axis
Y axis
Z axis
U axis
m+19
(0013)
m+47
(002F)
m+75
(004B)
m+103
(0067)
Acceleration/Decel
eration curve
With operating
command
The bit configuration for the word addresses in the above table is shown below.
15
00
0
0
0
X (= 0 or 1)
The acceleration/deceleration curve can be set to either of the following:
0000: Trapezoid
0001: S-curve
The default setting is 0000.
This setting specifies the curve to be used for acceleration and deceleration.
The following 3 parameters, along with the acceleration and deceleration time
data determine the rate of acceleration/deceleration for axes, and based on this
rate, the acceleration/deceleration time until the target speed is reached is
determined. (Refer to the diagram below.)
•
Acceleration/Deceleration curve
•
Maximum speed
•
Initial speed
Speed (pps)
Maximum speed
Target speed
Initial speed
Acceleration
time setting
Deceleration
time setting
Time
Actual axis
acceleration time
Actual axis
deceleration time
The acceleration and deceleration time data that is used for axis operation is
determined by the operation executed as shown in the table below.
Bit Configuration
Settings
Explanation