![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 104](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370104.webp)
4-6
Section
Memory Operation Data
91
Address
Default
setting
Configuration/Explanation
Name
Default
setting
Configuration/Explanation
Name
Default
setting
Configuration/Explanation
Name
NC1
j
3
Default
setting
Configuration/Explanation
Name
NC4
j
3
NC2
j
3
X axis
Default
setting
Configuration/Explanation
Name
U axis
Z axis
Y axis
12BC
12BD
22BC
22BD
32BC
32BD
42BC
42BD
Not used
Not used. Leave set to 0000.
0000
0000
12BE
12BF
22BE
22BF
32BE
32BF
42BE
42BF
Acceleration
time #1 (1
Hex)
rightmost
word
Acceleration
time #1 (1
Hex)
leftmost word
(2 words)
15
00
00 15
Acceleration #1 (leftmost word)
Acceleration #1 (rightmost word)
Sets acceleration time #1 (in ms units). The acceleration time can
be set in the range 0 to 250,000 ms as unsigned 32-bit hexadecimal
data using 2 words.
Setting range: 00000000 to 0003D090 Hex (0 to 250,000)
0000
0000
12C0
12C1
22C0
22C1
32C0
32C1
42C0
42C1
Acceleration
time #2
(2 Hex)
The settings are the same as for acceleration time #1.
0000
0000
to
to
to
to
to
---
12CC
12CD
22CC
22CD
32CC
32CD
42CC
42CD
Acceleration
time #8
(8 Hex)
The settings are the same as for acceleration time #1.
12CE
12CF
22CE
22CF
32CE
32CF
42CE
42CF
Acceleration
time #9
(9 Hex)
The settings are the same as for acceleration time #1.
12D0
12D1
22D0
22D1
32D0
32D1
42D0
42D1
Not used
Not used. Leave set to 0000.
0000
0000
12D2
12D3
22D2
22D3
32D2
32D3
42D2
42D3
Deceleration
time #1 (1
Hex)
rightmost
word
Deceleration
time #1 (1
Hex)
leftmost word
(2 words)
15
00
00 15
Deceleration #1 (leftmost word)
Deceleration #1 (rightmost word)
Sets deceleration time #1 (in ms units). The deceleration time can
be set in the range 0 to 250,000 ms as unsigned 32-bit hexadecimal
data using 2 words.
Setting range: 00000000 to 0003D090 Hex (0 to 250,000)
0000
0000
12D4
12D5
22D4
22D5
32D4
32D5
42D4
42D5
Deceleration
time #2
(2 Hex)
The settings are the same as for deceleration time #1.
to
to
to
to
to
---
12E0
12E1
22E0
22E1
32E0
32E1
42E0
42E1
Deceleration
time #8
(8 Hex)
The settings are the same as for deceleration time #1.
12E2
12E3
22E2
22E3
32E2
32E3
42E2
42E3
Deceleration
time #9
(9 Hex)
The settings are the same as for deceleration time #1.
12E4
22E4
32E4
42E4
Not used
Not used. Leave set to 0000.
0000
12E5
22E5
32E5
42E5
Dwell time #1
(01 Hex)
(1 word)
15
00
Dwell time #1
Sets dwell time #1 (in 0.01-ms units). The dwell time can be set in
the range 0.00 to 9.99 s as unsigned 16-bit hexadecimal data.
Setting range: 0000 to 03E7 Hex (0.00 to 9.99)
0000
12E6
22E6
32E6
42E6
Dwell time #2
(02 Hex)
The settings are the same as for dwell time #1.
to
to
to
to
to
---
12F6
22F6
32F6
42F6
Dwell time
#18 (12 Hex)
The settings are the same as for dwell time #1.
12F7
22F7
32F7
42F7
Dwell time
#19 (13 Hex)
The settings are the same as for dwell time #1.
Summary of Contents for CS1W-NC113 - REV 02-2008
Page 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Page 2: ...iv ...
Page 4: ...vi ...