10-2
Section
Memory Operation
194
Data Settings
The values for DM 1004 onwards are transferred when the power is turned on (or
at a restart).
Address
Setting
Contents of setting
1000
1001
Sequence #0 X axis designation
Completion code: automatic
Dwell time #0
1001
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1002
0301
Deceleration time #0
Initial speed #3
Target speed #1
1003
1002
Sequence #1 X axis designation
Completion code: continuous
Dwell time #0
1004
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1005
0301
Deceleration time #0
Initial speed #3
Target speed #1
1006
1002
Sequence #2 X axis designation
Completion code: continuous
Dwell time #0
1007
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1008
0302
Deceleration time #0
Initial speed #3
Target speed #2
1009
1003
Sequence #3 X axis designation
Completion code: bank end
Dwell time #0
1010
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1011
0300
Deceleration time #0
Initial speed #3
Target speed #0
Note
Addresses other than the above should be set to their factory values.
Address
Setting
Contents of setting
1300
0200
Speed #0
200 pps
1301
0300
Speed #1
300 pps
1302
0500
Speed #2
500 pps
1303
0000
Speed #3
0 pps
Note
Addresses other than the above should be set to their factory values.
Address
Setting
Contents of setting
1400
1200
Position #0
CW/incremental/1200 pulses
1401
2000
p
1402
1000
Position #1
CW/incremental/1000 pulses
1403
2000
p
1404
1000
Position #2
CW/incremental/1000 pulses
1405
2000
p
1406
1000
Position #3
CW/incremental/1000 pulses
1407
2000
p
Note
Addresses other than the above should be set to their factory values.
Acceleration and deceleration times use the values in the parameter area, so
this data area needs to be set completely to the factory settings.
Dwell times are not used in these programs, so this data area needs to be set
completely to the factory settings.
Zones are not used in these programs, so this data area needs to be set com-
pletely to the factory settings.
Axis Parameters
Positioning Sequences
Speeds
Positions
Acceleration and
Deceleration Times
Dwell Times
Zones
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...