![Omron C200HW Operation Manual Download Page 40](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329040.webp)
!
2-3
Section
External I/O Circuitry
27
2-3-3 I/O Circuitry
Outputs
Constant
voltage
circuit
Output power supply, 24 VDC
Output GND, 24 VDC
CW pulse/pulse output
(with 1.6 k
Ω
resistance)
CW pulse output
CCW pulse/direction output
(with 1.6 k
Ω
resistance)
CCW pulse/direction output
Error counter reset output (with 1.6 k
Ω
resistance)
Origin-adjustment command output (with
1.6 k
Ω
resistance)
1.6 k
Ω
(1/2W)
1.6 k
Ω
(1/2W)
Note
Output switching depends on the
axis parameter settings. (Refer to
4-3 Axis Parameters Area
.)
Error counter reset output
Origin-adjustment command output
1.6 k
Ω
(1/2W)
See
note.
The pulse output and error counter reset circuitry of the Position Control Unit are
provided with two types of terminals: terminals with 1.6 k
Ω
(1/2 W) limit resis-
tance and terminals with no resistance. Select the terminals in accordance with
the power requirements and the specifications of the motor driver to be used.
Caution
Connect a load of 7 to 30 mA (or 7 to 16 mA for terminals with 1.6 k
Ω
limit resis-
tance) to the output section. If a current greater than this is used, it will cause
damage to the PCU’s internal components. Also, be sure to use the CW/CCW
output method when using pulse output terminals with limit resistance.
Open collector output
Open collector output with 1.6 k
Ω
series resistance
Output
7 to 30 mA
Output transistor
Output
7 to 13 mA
Output Circuitry
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...