![Omron C200HW Operation Manual Download Page 80](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329080.webp)
4-1
Section
Overall Structure
67
Operation Mode Selection
X axis 0005 (NC113), Y axis 0029 (NC213), Z axis 0053 and U axis 0077
(NC413)
15
00
Origin search direction
Origin detection method
Origin search operation
Operation mode
12
11
08
07
04
03
Bit
Item
Settings
00 to 03
Operation mode
0 (Mode 0): Uses stepping motor, and uses
external sensor signal as origin input signal.
1 (Mode 1): Uses servomotor driver, and
uses encoder’s Z-phase signal for origin
input signal. Does not use positioning
completed signal.
2 (Mode 2): Same as Mode 1, but uses
positioning completed signal.
3 (Mode 3): Uses OMRON H-Series or
M-Series Servomotor Driver. Origin search is
completed by Servomotor Driver’s origin
adjustment command. Uses positioning
completed signal.
04 to 07
Origin search operation
0: Reverse mode 1 (reverse at limit input)
Detects origin in designated origin search
direction.
1: Reverse mode 2 (error stop at limit input)
Detects origin in designated origin search
direction.
2: Single-direction mode (No reverse)
08 to 11
Origin detection
method
0: Takes origin input signal after origin
proximity input signal turns ON (
↑
) and OFF
(
↓
).
1: Takes origin input signal after origin
proximity input signal turns ON (
↑
).
2: Takes origin input signal without using
origin proximity input signal.
3: Takes origin input signal after limit input
signal turns ON (
↑
) and OFF (
↓
), or OFF (
↓
),
without using origin proximity input signal.
(enabled only for single-direction mode.)
12 to 15
Origin search direction
0: CW direction
1: CCW direction
Default Setting: 0000
Note
Once the I/O settings have been specified, they are enabled by turning on the
power or restarting the Unit. If the settings have been specified by data transfer,
save the data and then turn on the power or restart the Unit.
The other parameters for each axis are enabled at the point of transfer and from
the following command operations.
Maximum Speed
X axis 0006 (NC113), Y axis 0030 (NC213), Z axis 0054 and U axis 0078
(NC413)
15
00
Factor
x10
3
x10
2
x10
1
x10
0
14
13
12
Factor: 00: x1, 01: x10, 10: x100, 11: x1,000 (pps)
Default Setting: C500
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...