1, 2, 3...
1. When the operation start switch is turned ON, the program outputs
1,200 pulses CW on the X axis and stops.
2. When the operation start switch is turned ON, the program outputs
1,000 pulses CW on the X axis and stops.
When the operation start switch is again turned ON, the program outputs
1,000 pulses CW on the X axis and stops.
When the operation start switch is again turned ON, the program outputs
1,000 pulses CW on the X axis and stops.
When the Operation Checking Switch is OFF
1, 2, 3...
1. When the operation start switch is turned ON, the program outputs
1,000 pulses CW on the X axis and stops, and immediately moves to the
positioning in the next step (2, below). (Automatic)
2. Using continuous positioning, the program outputs 3000 pulses CW on the
X axis and stops. (Continuous)
Setting the Unit
Unit Number: Unit #0
Unit Used:
NC113
Data Memory Settings
DM
Setting
Contents of setting
DM
Setting
Contents of setting
1000
000D
Sets the operating data area to
DM 0500 onwards.
1014
****
Acceleration/deceleration curve:
trapezoid
1001
0500
0500 o
a ds
1015
0010
Acceleration time (from 0 to
i
d) 10
1002
0001
Not mounted to Slave. DM 1004
onwards used for parameter
transfer.
1016
0000
(
maximum speed): 10 ms
1003
****
Reserved
1017
0010
Deceleration time (from
i
d
0) 10
1004
****
I/O setting
1018
0000
(
maximum speed to 0): 10 ms
1005
***#
Operation mode/origin search
1019
****
Positioning monitor time
1006
0500
Maximum speed: 500 pps
1020
****
CCW software limit
1007
****
Initial speed
1021
****
1008
0500
Origin search high speed
1022
****
CW software limit
1009
0100
Origin search proximity speed
1023
****
1010
****
Origin compensation
1024
****
Reserved
1011
****
g
p
1025
****
1012
****
Backlash compensation
1026
****
1013
****
Backlash compensation speed
1027
****
Note
Set the items marked in the table with asterisks (*) to their factory settings.
Set the operation mode of items marked in the table with a hash mark (#) to
accord with the motor and driver.
Designation of the Operating Data Area
The operating data area is allocated to DM 0500 through DM 0533 according to
the data memory settings. The operating data area is not used in the following
program examples, so it is not set.
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...