![Omron C200HW Operation Manual Download Page 213](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329213.webp)
10-2
Section
Memory Operation
204
Address
Setting
Contents of settings
1400
1000
Position #0
CW/absolute/1,000 pulses
1401
0000
,
p
1402
1500
Position #1
CW/incremental/1,500 pulses
1403
2000
,
p
1404
1000
Position #2
CW/incremental/1,000 pulses
1405
2000
,
p
1406
1000
Position #3
CW/incremental/1,000 pulses
1407
2000
,
p
1408
1000
Position #4
CW/absolute/1,000 pulses
1409
0000
,
p
1410
0000
Position #5
CW/absolute/0 pulses
1411
0000
p
Note
Addresses other than the above should be set to their factory values.
Address
Setting
Contents of settings
1602
0005
Acceleration #1
5 ms
1603
0000
1604
0020
Acceleration #2
20 ms
1605
0000
1622
0005
Deceleration #1
5 ms
1623
0000
1624
0020
Deceleration #2
20 ms
1625
0000
Note
Addresses other than the above should be set to their factory values.
Dwell times are not used in these programs, so this data area needs to be set
completely to the factory settings.
Zones are not used in these programs, so this data area needs to be set com-
pletely to the factory settings.
Positions
Acceleration and
Deceleration Times
Dwell Times
Zones
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...