![Omron C200HW Operation Manual Download Page 227](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329227.webp)
10-6
Section
Override
218
10-6 Override
10-6-1 Changing Speed During Continuous Output
Overview
•
Override can be used to change the speed during pulse output.
•
The target speed is determined by the override coefficient set in the operating
data area.
•
In order to use the actual target speed that has been set, either disable the
override or set it to 100%.
Operation Example
The following is an example of changing the speed with override during continu-
ous operation.
Operation
starts
Speed (pps)
Time
Speed
change 1
Speed
change 2
Speed
change 3
Operation
stops
1, 2, 3...
1. When the operation start switch is turned ON, continuous output is executed
at a speed of 300 pps CW on the X axis.
2. When speed change switch 1 is turned ON, the continuous output deceler-
ates to a speed of 150 pps.
3. When speed change switch 2 is turned ON, the continuous output acceler-
ates to a speed of 500 pps.
4. When speed change switch 3 is turned ON, the output continues at a speed
of 300 pps.
5. When the operation start switch is turned OFF, the output of X axis stops.
Setting the Unit
Unit Number: Unit #0
Unit Used:
NC113