![Omron C200HW Operation Manual Download Page 21](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329021.webp)
1-3
Section
Basic Operations
8
When an interrupt input signal is received, positioning is continued for the speci-
fied amount of pulses and then stopped.
Time
Interrupt input signal
Specified amount
of pulses
Speed
1-3-2 Speed Control
When a start is executed once, pulses are continuously output at a constant rate.
The pattern depends on the completion code that is set for “memory operation”
positioning sequences. To stop the sequence, use the STOP command.
Time
Start
STOP
Speed
1-3-3 Other Operations
The origin search operation finds the origin for the designated axis.
The jogging operation moves a specified axis at a designated speed and then
stops it.
The teaching operation takes the present position for the specified positioning
sequence.
Present position
Origin
Specified positioning sequence number
Interrupt Feeding
Origin Search
Jogging
Teaching