1-6
Section
Before Operation
16
2. The user can select whether to use the axis parameters set in Data Memory
or the axis parameters saved at the PCU.
3. All saved data is automatically read to the PCU’s internal memory when the
PCU is powered up. If the common parameters are set so that data saved at
the PCU is used, then the axis parameters will be automatically read at pow-
er-up.
4. For operations that cannot be performed when the origin is not established,
it will be necessary to first execute an origin search or a present position
change to establish the origin.
5. For the operational flow when an error or alarm is generated, refer to
Section
11 Troubleshooting
.
6. When powering up or restarting the PCU, wait for the X-axis Busy Flag to
turn OFF before executing any commands.