![Omron C200HW Operation Manual Download Page 82](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329082.webp)
4-1
Section
Overall Structure
69
Range: 0 to 9,999 (pulses)
Default Setting: 0000
Backlash Compensation Speed
X axis 0013 (NC113), Y axis 0037 (NC213), Z axis 0061 and U axis 0085
(NC413)
15
00
x10
3
x10
2
x10
1
x10
0
14
13
12
Factor
Factor: 00: x1, 01: x10, 10: x100, 11: x1,000 (pps)
Default Setting: 0000
Acceleration/Deceleration Curve
X axis 0014 (NC113), Y axis 0038 (NC213), Z axis 0062 and U axis 0086
(NC413)
15
00
0
0
0
Designation
Designation:
0: Trapezoid; 1: S-curve
Default setting: 0000
Acceleration Time (Rightmost Word)
X axis 0015 (NC113), Y axis 0039 (NC213), Z axis 0063 and U axis 0087
(NC413)
Acceleration Time (Leftmost Word)
X axis 0016 (NC113), Y axis 0040 (NC213), Z axis 0064 and U axis 0088
(NC413)
15
00
0
0
x10
5
x10
4
x10
3
x10
2
x10
1
x10
0
00
15
Leftmost word
Rightmost word
Range: 0 to 250,000 (ms)
Default Setting: 0100, 0000
Deceleration Time (Rightmost Word)
X axis 0017 (NC113), Y axis 0041 (NC213), Z axis 0065 and U axis 0089
(NC413)
Deceleration Time (Leftmost Word)
X axis 0018 (NC113), Y axis 0042 (NC213), Z axis 0066 and U axis 0090
(NC413)
15
00
0
0
x10
5
x10
4
x10
3
x10
2
x10
1
x10
0
00
15
Leftmost word
Rightmost word
Range: 0 to 250,000 (ms)
Default Setting: 0100, 0000
Positioning Monitor Time
X axis 0019 (NC113), Y axis 0043 (NC213), Z axis 0067 and U axis 0091
(NC413)
15
00
x10
3
x10
2
x10
1
x10
0
Range: 0 to 9,999 (ms)
Enabled for operation modes 2 and 3.
Default Setting: 9999
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...