![Omron C200HW Operation Manual Download Page 135](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329135.webp)
6-2
Section
Executing Origin Search
123
Origin detection method
Origin search operation
2: Single direction mode
1: Takes origin signal after origin
proximity signal turns ON (
↑
).
Note
A limit signal is input and operation is stopped without deceleration.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Stop
CW limit (See note.)
Limit Stop (Error Code: 6200)
Start
CW limit (See note.)
Limit Stop
(Error Code: 6200)
Start
2: Origin proximity input signal not
used
Note
A limit signal is input and operation is stopped without deceleration.
Origin input signal
Pulse output
Start
Stop
CW limit (See note.)
Limit Stop (Error Code: 6201)
Start
CW limit (See note.)
Limit Stop
(Error Code: 6201)
Start
Origin search proximity speed
3: Limit input signal used instead of
origin proximity input signal
Note
A limit signal is input and operation is stopped without deceleration.
CCW limit input
Origin input signal
Pulse output
Start
Stop
Start
CW limit (See note.)
Limit Stop
(Error Code: 6200)
Start
Stop
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...