![Omron C200HW Operation Manual Download Page 221](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329221.webp)
10-4
Section
Linear Interpolation
212
Data Memory Settings
DM
Setting
Contents of setting
DM
Setting
Contents of setting
1000
000D
Sets the operating data area to
DM 0500
d
1024
****
Reserved
1001
0500
p
g
DM 0500 onwards
1025
****
1002
0001
Not mounted to a Slave.
DM 1004 onwards used for
parameter transfer
1026
****
1003
****
Reserved
1027
****
1004
****
I/O setting
1028
****
I/O setting
1005
***#
Operation mode/origin search
1029
****
Operation mode/origin search
1006
0500
Maximum speed: 500 pps
1030
0500
Maximum speed: 500 pps
1007
****
Initial speed
1031
****
Initial speed
1008
0500
Origin search high speed
1032
0500
Origin search high speed
1009
0100
Origin search proximity speed
1033
0100
Origin search proximity speed
1010
****
Origin compensation value
1034
****
Origin compensation value
1011
****
g
p
1035
****
g
p
1012
****
Backlash compensation value
1036
****
Backlash compensation value
1013
****
Backlash compensation speed
1037
****
Backlash compensation speed
1014
****
Acceleration/deceleration curve:
trapezoid
1038
****
Acceleration/deceleration curve:
trapezoid
1015
0010
Acceleration time (from 0 to
i
d) 10
1039
0010
Acceleration time (from 0 to
i
d) 10
1016
0000
(
maximum speed): 10 ms
1040
0000
(
maximum speed): 10 ms
1017
0010
Deceleration time (from
i
d
0) 10
1041
0010
Deceleration time (from
i
d
0) 10
1018
0000
(
maximum speed to 0): 10 ms
1042
0000
(
maximum speed to 0): 10 ms
1019
****
Positioning monitor time
1043
****
Positioning monitor time
1020
****
CCW software limit
1044
****
CCW software limit
1021
****
1045
****
1022
****
CW software limit
1046
****
CW software limit
1023
****
1047
****
Note
Set the items marked in the table with asterisks (*) to their factory settings.
Set the operation mode of those items marked in the table with a hash mark (#) to
accord with the motor and driver.
Designation of the Operating Data Area
The operating data area is allocated to DM 0500 through DM 0533 by the data
memory settings. In this program example, the operating data area is not set
because it is not used.
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...