![Omron C200HW Operation Manual Download Page 205](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329205.webp)
10-2
Section
Memory Operation
196
10-2-2 Repeat Operation
Overview
•
Any operation can be executed repeatedly under memory operation using the
bank end completion code.
•
When the completion code of any positioning sequence is set to bank end,
positioning is stopped after the operation for that sequence has been com-
pleted.
•
When operation is started again, it returns to the sequence number that was
previously enabled and executes the positioning.
Operation Example
The following is an example of repeating a particular operation.
Operation
starts
Operation
starts
Operation
starts
Speed (pps)
X axis
1, 2, 3...
1. When the operation start switch is turned ON at the origin, the program out-
puts 1,000 pulses CW on the X axis and stops. (Independent)
(First, set the origin to “0” either by performing an origin search or by execut-
ing PRESENT POSITION CHANGE.)
2. When the operation start switch turns ON, positioning is executed using the
continuous completion code, and the program positions to 4,500 pulses CW
on the X axis and stops.
3. When the operation start switch turns ON, positioning is executed using the
continuous completion code. The program positions to the X axis origin and
stops.
4. When the operation start switch turns ON, the operations in steps 1 to 3
above are repeated.
Setting the Unit
Unit Number: Unit #0
Unit Used:
NC113
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...