![Omron C200HW Operation Manual Download Page 165](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329165.webp)
8-3
Section
Operations With Memory Operation
155
Operating Memory Area
Item
Model
Operating memory area
Bits
Contents
X axis
Y axis
Z axis
U axis
START
NC413
n
n+2
n+4
n+6
01
: Start begins
INDEPENDENT
START
NC213
NC113
n
n
n+2
02
: Independent start begins
Sequence number
enable
NC113
n
00
1: Enable, 0: disable
Sequence number
NC413
NC213
NC113
n+1
n+1
n+1
n+3
n+3
n+5
n+7
00 to
07
Designates sequence number (from 00
through 99) in BCD.
Waiting for memory
operation
NC413
NC213
n+8
n+4
n+11
n+7
n+14
n+17
04
1: Waiting for memory operation
0: Other than above
Positioning
completed
NC113
n+2
05
: Positioning operation completed
: When starting
Busy Flag
13
1: Busy
Output code
00 to
03
The output code (from 0 through F) set in
the positioning sequence is output in
hexadecimal.
Note
1. When positioning is executed with positions designated as absolute, a pres-
ent position unknown error (error code 5040) will be generated if the origin
has not been established.
2. If the software limit for axis parameters is disabled (CW limit equal to or less
than CCW limit), and if the designation is made while the origin is estab-
lished (No Origin Flag OFF), positioning will be carried out by a relative
amount, even with absolute position data. (Present position is “0” at the time
of designation.)
8-3
Operations With Memory Operation
The following positioning can be carried out according to the positioning
sequence settings.
8-3-1 Starting Memory Operation
There are two ways of starting memory operation, as follows:
1. Turn the START Bit from OFF to ON (
).
2. Turn the INDEPENDENT START Bit from OFF to ON (
).
Executes the same number position as the positioning sequence, according to
the completion code in the positioning sequence.
Does not comply with the completion code in the positioning sequence, but
always works as a terminating completion. A bank end completion(completion
code 3), however, still works as a bank end operation.
8-3-2 Memory Operation In Accordance With Positioning Sequences
Positioning with memory operation is controlled by data set for the positioning
sequences.
Target speed
Initial speed
Accelera-
tion time
Decelera-
tion time
Completion code
When Executed by
START
When Executed by
INDEPENDENT START
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...