4-1
Section
Overall Structure
57
C200HW-NC113/213 PCUs occupy 10 words in the IR Area for Special I/O
Units, and C200HW-NC413 PCUs occupy 20 words in that area.
IR 100 to IR 109
IR 110 to IR 119
IR 120 to IR 129
IR 130 to IR 139
IR 140 to IR 149
IR 150 to IR 159
IR 160 to IR 169
IR 170 to IR 179
IR 180 to IR 189
IR 190 to IR 199
IR 400 to IR 409
IR 410 to IR 419
IR 420 to IR 429
IR 430 to IR 439
IR 440 to IR 449
IR 450 to IR 459
n to n+1
n+2 to n+4
C200HW-NC113/NC213
C200HW-NC413
IR 100 to IR 119
IR 110 to IR 129
IR 120 to IR 139
IR 130 to IR 149
IR 140 to IR 159
IR 150 to IR 169
IR 160 to IR 179
IR 170 to IR 189
IR 180 to IR 199
IR 400 to IR 419
IR 410 to IR 429
IR 420 to IR 439
IR 430 to IR 449
IR 440 to IR 459
n to n+1
n+2 to n+3
n+4 to n+5
n+6 to n+7
n+8 to n+10
n+11 to n+13
n+14 to n+16
n+17 to n+19
I/O
Output
Input
Word address
Axis
X axis
X axis
I/O
Output
Input
Word address
Axis
X axis
Y axis
Z axis
U axis
X axis
Y axis
Z axis
U axis
C200HW-NC413
Unit #0
Unit #1
Unit #2
Unit #3
Unit #4
Unit #5
Unit #6
Unit #7
Unit #8
Unit #9
Unit #A
Unit #B
Unit #C
Unit #D
Unit #E
Unit #F
Unit #0
Unit #1
Unit #2
Unit #3
Unit #4
Unit #5
Unit #6
Unit #7
Unit #8
Unit #A
Unit #B
Unit #C
Unit #D
Unit #E
C200HW-NC413
n to n+1
n+2 to n+3
n+4 to n+6
n+7 to n+9
I/O
Output
Input
Word address
Axis
X axis
Y axis
X axis
Y axis
C200HW-NC213
n: 100+10 x Unit No. (Unit No.
x
9)
400+10 x (Unit No. - 10) (Unit No.
y
A(10))
Note
1. The C200HW-NC413 occupies the space for two unit numbers, i.e., the unit
number that is set and also the following number. For example, if the unit
number is set to 0, then the area for unit numbers 0 and 1 is allocated.
2. Be sure to set the unit numbers so that they do not overlap with the unit num-
bers of other Special I/O Units.
3. Since the C200HW-NC413 occupies the space for two unit numbers, it can-
not be set for unit numbers 9 or F.
Depending on the model of the Programmable Controller that is used, it may not
be possible to set PCU unit numbers from A to F (E). Please check the operation
manual of the Programmable Controller.
For details regarding operating memory area settings, refer to
Parameter Areas
under
4-1-4 Data Areas
and
4-2 Common Parameter Area
.
0
m
15
00
Common Parameter Area
0
0
0
x: D (DM area), E (EM area)
x10
3
m+1
x10
2
x10
1
x10
0
Beginning word address
I
C200HW-NC113
I/O
Word address
Axis
Output
I to I+5
Common
p
I+6 to I+10
X axis
Input
I+11 to I+12
X axis
Operating Memory Area
(IR Area)
Operating Memory Area
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...