6-2
Section
Executing Origin Search
125
Origin Detection Method: 0
When the deceleration time is short, such as in cases where positioning begins
from within the origin proximity area, an origin input signal will be detected
immediately after the falling edge of the origin proximity input signal. Be sure that
the origin proximity input signal dog is long enough (i.e., more than the decelera-
tion time).
Origin
proximity
input signal
Pulse
output
Start
Stop
Logical position for origin
proximity input signal OFF.
Stop
Start
Origin input
signal
(Z-phase
signal)
Origin Detection Method: 1
If an origin proximity input signal is input during deceleration, the stop position
will vary according to the length of the deceleration time.
Origin
proximity
input signal
Pulse
output
Start
Stop
Origin input
signal
(Z-phase
signal)
(When the deceleration
time is long.)
(When the deceleration
time is short.)
Start
Stop