![Omron C200HW Operation Manual Download Page 13](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329013.webp)
5
Application Precautions
xvi
•
Tighten the PC mounting screws, terminal block screws, and cable screws to
the torque specified in this manuals.
•
Always use the power supply voltage specified in this manual.
•
Take appropriate measures to ensure that the specified power with the rated
voltage and frequency is supplied. Be particularly careful in places where the
power supply is unstable.
•
Use crimp terminals for wiring. Do not connect bare stranded wires directly to
terminals.
•
Leave the dustproof labels affixed to the top of the Unit when wiring. After wir-
ing, remove the labels for proper heat radiation.
•
Do not apply voltages to the Input Units in excess of the rated input voltage.
•
Do not apply voltages or connect loads to the Output Units in excess of the
maximum switching capacity.
•
Check the user program for proper execution before actually running it in the
Unit.
•
Be sure that the terminal blocks, memory units, extension cables, and other
items with locking devices are properly locked.
•
Double-check all the wiring before turning on the power supply.
•
Disconnect the functional ground terminal when performing withstand voltage
tests.
•
Confirm that no adverse effect will occur in the system before performing the
following operations:
•
Changing the operating mode of the PC.
•
Force-setting/resetting the relay contacts.
•
Changing the present values or set values.
•
Changing positioning data or parameters.
•
Resume operation only after transferring to the new CPU Unit the contents of
the DM and HR Areas required for operation.
•
Do not attempt to disassemble, repair, or modify any Units.
•
Do not pull on or bend the cables beyond their natural limit. Doing so may break
the cables.
•
Do not place heavy objects on top of the cables. Doing so may break the
cables.
•
Resume operation only after saving in the Position Control Unit the parameters
and position data required for resuming operation.
•
Be sure that the set parameters and data operate properly.
•
Be sure to check the pin numbers before wiring the connectors.
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...