![Omron C200HW Operation Manual Download Page 107](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329107.webp)
4-8
Section
Setting Data for Unused Axes
94
Address
Name
Description
Default
tti
NC113
NC213
NC413
p
setting
(see
X axis
Y axis
Z axis
U axis
(see
note)
m+4
m+28
m+52
m+76
I/O settings
Even if these settings are not made for unused
axes, there will be no affect on the operation of the
used axes. Depending on the wiring, however,
sensor input errors will be generated for unused
axes. To eliminate sensor input errors, perform
wiring so that emergency stop input and limit input
are ON. (Refer to
2-6 Connection of Unused Axes
.)
Using bit 04 in the following way, it is possible to
eliminate the need for wiring the limit input signal.
Bit 04 (limit input signal type)
0: N.C. input
With this setting, it is necessary to
connect an input power supply
and supply power.
1: N.O. input
With this setting, wiring is not
necessary (since the signal will be
deemed to be ON).
0060
m+6
m+30
m+54
m+78
Maximum
speed
Make these settings so that the following condition
is satisfied:
0
t
Origin search proximity speed
t
Origin search
C500
m+8
m+32
m+56
m+80
Origin search
high speed
0
t
Origin search proximity speed
t
Origin search
high speed
x
Maximum speed
Example
8250
m+9
m+33
m+57
m+81
Origin search
proximity speed
Example
Maximum speed:
C500 (500,000 pps)
Origin search high speed:
C500 (500,000 pps)
Origin search proximity speed: C010 (10,000 pps)
4250
Note
The default settings are those saved in the PCU’s flash memory.
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...