![Omron C200HW Operation Manual Download Page 231](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329231.webp)
10-7
Section
Transferring and Saving Data
222
Data Memory Settings
DM
Setting
Contents of setting
1000
000D
Sets the operating data area to DM 0500 onwards.
1001
0500
1002
0000
Not mounted to Slave. No parameters transferred.
The parameters for each axis are read from the flash memory of the Position
Control Unit. Transfer them in advance to the Position Control Unit and then
save them.
WRITE DATA and SAVE DATA
DM
Setting
Contents of setting
1200
000D
Set the operating data area to DM 0600 onwards.
1201
0600
1202
0000
Not mounted to Slave. No parameters transferred.
Designation of the Operating Data Area
The operating data area is set during programming and therefore no setting is
necessary beforehand.
Data Settings
READ DATA
•
Axis Parameters
•
Positioning Sequences
•
Speeds
•
Positions
•
Acceleration and Deceleration Times
•
Dwell Times
•
Zones
Transfer the data needed for the operation beforehand to the Position Control
Unit for both the X and Y axes, and save it in the flash memory.
The data in DM 3000 through DM 3694 is transferred to the Position Control Unit,
so set all the data such as the axis parameters, positioning sequences, speeds
and so on, in this DM area.
READ DATA
C200HW-NC213
C200HW-NC113
WRITE DATA and SAVE
DATA
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...