3-2
Section
System Configuration and Wiring
50
Use the rotary switch on the front panel of the PCU to set the unit number (i.e.,
the machine No.).
MACHINE No.
0
For details regarding rotary switch settings, refer to
2-2 Components
.
Wire the system as shown in the following diagram. The CW limit input, CCW
limit input, and emergency stop input are factory set as N.C. terminals, so short-
circuit them.
Position Control Unit
CW pulse output
(with 1.6 k
Ω
resistance)
24-V
power
supply
for
output
24-V
GND for
output
Input
common
CCW
limit
output
Stepping motor driver
Stepping motor
PK543-NAC
(Oriental Motor Co.)
DFU1507
(Oriental Motor Co.)
24-VDC power supply
Emergency
stop
input
signal
CCW pulse output
(with 1.6 k
Ω
resistance)
CW limit
output
24-VDC power supply
For details on connecting the PCU and the stepping motor driver, refer to the
motor driver specifications and also
Section 2 Specifications and Wiring
.
(2) Rotary Switch Setting
(3) Wiring