![Omron C200HW Operation Manual Download Page 275](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329275.webp)
Appendix F
Using with CS1-series PCs
269
Transfer Using the IOWR Instruction
A sample program is provided below for writing the indicated speed data to the Position Control Unit. The begin-
ning word address of the transfer data is to be D00500, and the other settings are as indicated. The data will be
transferred to the Position Control Unit designated as unit number 2.
Data
Address (transfer
destination)
DM (transfer source)
Setting
Speed #0
1300
D00500
1000
Speed #1
1301
D00501
5500
Write switch
a
c
b
Equals Flag
b
c
“b” turns ON when transfer has been
completed normally.
C
S
W
Beginning word address for the transfer
destination in the Position Control Unit.
Beginning word address for the transfer
source in the CPU Unit.
D00400:
Unit number (Hex)
Number of transfer
words (Hex)
a
DIFU(013)
IOWR
#1300
D00500
D00400
0 0 0 2
0 0 0 2