Appendix F
Using with CS1-series PCs
265
Operating Data Area (DM or EM Area)
Bit
Common (data
transfer information)
Positions, speeds, etc.
Transfer designations for
memory operation data
Positions, speeds, and
acceleration/deceleration
times used for direct
operation
I is specified in the common
parameter area (in DM or EM area)
15
0
Status
Positioning sequence being
executed (memory operation),
I/O signal status for the axes,
error codes
Contents
Word I
to
Word I+5
Word I+6
to
Word I+25
Word I+26
to
Word I+31
CPU Unit
→
PCU
PCU
→
CPU Unit
CPU Unit
→
PCU
Direction
Data Transfer Area (DM or EM Area)
Word k
onwards
Memory
operation
data
15
0
Contents
Bit
k is specified in the operating data area (DM or EM area)
Data for memory operation
CPU Unit
→
PCU
or
PCU
→
CPU Unit
Direction
Setup Procedure
Hardware Settings
1, 2, 3...
1. Set the unit number using the rotary switch on the front of the PCU.
2. Mount to a CS1 CPU Rack, a C200H Expansion I/O Rack, a CS1 Expansion
Rack, or a SYSMAC BUS Remote I/O Slave Rack. In a basic system, up to
16 C200HW-NC113/213 PCUs or up to 8 C200HW-NC413 PCUs can be
mounted. (There are no restrictions on the mounting order.)
3. Connect external I/O for the axes.
4. Connect the Programming Device for the PC.
5. Turn ON power for the PC.
6. Create an I/O table.
Software Settings
1, 2, 3...
1. Make the common parameter and axis parameter settings in words m to
m+99 in the DM area. These settings are required for both direct operation
and memory operation.
2. Make the operating data area settings in words I to I+33 of the DM or EM
area (designated with the common parameters). These settings are
required for both direct operation and memory operation.
3. Make the data transfer area settings in words k onwards of the DM or EM
area (designated in the operating data area). These settings determine
operation when a data transfer operation is executed from the operating
memory area. They are not required for direct operation but are required for
memory operation (unless required data is transferred using SYSMAC-
NCT).
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...