2-5
Section
Connections in Each Operating Mode
38
Parameter Setting Example
0
0
6
0
m+4
0
1
0
0
m+5
15
0
Word
Bits
Setting
Contents
m+4
00
0
CW/CCW output
01 to 03
0
---
04
0
Limit input: N.C. contact
05
1
Origin proximity input signal: N.O.
contact
06
1
Origin input signal: N.O. contact
07
0
Pulse output stopped with
emergency stop input signal.
08 to 15
0
---
m+5
00 to 03
0
Mode 0
04 to 07
0
Reverse mode 1
08 to 11
1
Takes origin input signal after origin
proximity input signal is received.
12 to 15
0
Search direction: CW
Note
“m” is the beginning DM word allocated when the unit number is set.
Origin Search Operation
The origin search operation is completed with the rising edge of the origin input
signal after the rising edge of the origin proximity input signal.
ORIGIN
SEARCH
Origin proximity
input signal
Origin input
signal
Pulse output
Busy Flag
Time
Summary of Contents for C200HW