![Omron C200HW Operation Manual Download Page 104](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329104.webp)
4-6
Section
Positioning Sequence Details
91
Sequence #1: Terminating completion (output code: 4)
Sequence #2: Automatic completion (output code: 6)
Sequence #3: Bank end completion (output code: 8)
Sequence number
Sequence no. enable
START
Pulse output
Positioning
completed
Output code
Speed
Sequence
#0
Sequence #1
Sequence #2
Dwell
time
Seq.
#3
Time
Busy
Memory operating
waiting
2
The seven completion codes are described below.
Code
Name
Description
Operation
0
Terminating
The sequence is executed, and
then positioning is stopped until
START is executed for the next
sequence.
Target speed
Deceleration
Stopped at
initial speed
Acceleration
Initial
speed
Time
START
Target position
1
Automatic
The sequence is executed, and
then positioning is paused for the
duration of the dwell time before the
next sequence is started
automatically.
Target speed
Next sequence started
Time
START
Dwell time
2
Continuous
The sequence is executed, and
then positioning continues with the
next sequence without stopping at
the target position. (If a dwell time is
set, however, then positioning will
pause for the duration of the dwell
time.)
Target speed
Target position passed without
stopping.
Time
START
Target speed for
next sequence
3
Bank end
Positioning is stopped after
completion. When START is next
executed, positioning starts again
with the sequence designated by
the “sequence number enable”
setting.
Target speed
Time
START
Positioning stopped
Completion Code
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...