![Omron C200HW Operation Manual Download Page 273](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329273.webp)
Appendix F
Using with CS1-series PCs
267
Programming
Direct Operation
The following program example transfers position data already set in the DM area in order.
Operation start switch
Busy Flag
No Origin Flag
Turns a ON for one cycle when
the operation turns ON.
Transfers positioning data set in the DM
area to the operating data area.
The contents of the 5 words starting
from word set in D00020 are trans-
ferred to the 5 words in the operating
data area starting from D00506 contain-
ing position, speed, and acceleration/
deceleration time settings for the axes.
Adds 5 to the pointer, D00020.
Indicates end of positioning data.
(This flag turns ON when contents
of the pointer, D00020 are #0020.)
Initializes (i.e., sets to #0000)
the contents of the pointer
(D00020) when the Equals
Flag turns ON.
First Cycle Flag
200213
(word n+2, bit 13)
200206
(word n+2, bit 06)
A20011
(Auxiliary Area)
200003
(word n, bit 03)
a
ABSOLUTE MOVEMENT
Equals Flag
Initializes (i.e., sets to #0000) the
contents of the pointer, D00020.
DIFU(013)
a
XFER(070)
#0005
*D00020
D00506
+B(404)
#0005
D00020
D00020
CMP(020)
#0020
D00020
D00020
MOV(021)
#0000
MOV(021)
D00020
#0000
Summary of Contents for C200HW