![Omron C200HW Operation Manual Download Page 184](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329184.webp)
9-4
Section
Forced Interrupt
175
9-3-5 Timing Chart
The following timing chart illustrates interrupt feeding under direct operation,
using the X axis as an example. There is a movement of 10,000 pulses in the
direction of travel.
Position
(I+7, I+6)
Speed
(I+8)
Direction designation
(word n, bit 10)
Interrupt feed
(word n, bit 5)
Interrupt input signal
(input to Position
Control Unit)
(A19/B19)
Speed
Pulse output
Positioning Completed
(word n+8, bit 05)
Busy Flag
(word n+8, bit 13)
Time
10,000 pulses
(Interrupt feeding in the direction of travel)
9-4
Forced Interrupt
FORCED INTERRUPT is a command which is only enabled during memory
operation. It is used for taking emergency evasive action from the current opera-
tion under memory operation.
When a sequence number with the forced interrupt operation set is specified and
the FORCED INTERRUPT Bit is turned ON, the pulse output of the memory
operation currently being executed is stopped (without deceleration) and posi-
tioning is executed from the specified sequence number. There is no need to
turn ON the Sequence Number Enable Bit.
Procedure for Using Forced Interrupt
1, 2, 3...
1. Set the forced interrupt action in the positioning sequence and transfer it to
the Position Control Unit.
2. When a forced interrupt is required, specify the sequence number set in (1)
and FORCED INTERRUPT from OFF to ON.
Outline of Operation
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...