10-2
Section
Memory Operation
203
Address
Setting
Contents of setting
1000
1000
Sequence #0 X axis designation
Completion code: terminating
Dwell time #0
1001
0011
Dwell time #0
Acceleration time #1
Deceleration time #1
1002
0401
Deceleration time #1
Initial speed #4
Target speed #1
1003
1002
Sequence #1 X axis designation
Completion code: continuous
Dwell time #0
1004
0022
Dwell time #0
Acceleration time #2
Deceleration time #2
1005
0403
Deceleration time #2
Initial speed #4
Target speed #3
1006
1002
Sequence #2 X axis designation
Completion code: continuous
Dwell time #0
1007
0022
Dwell time #0
Acceleration time #2
Deceleration time #2
1008
0401
Deceleration time #2
Initial speed #4
Target speed #1
1009
1003
Sequence #3 X axis designation
Completion code: bank end
Dwell time #0
1010
0022
Dwell time #0
Acceleration time #2
Deceleration time #2
1011
0402
Deceleration time #2
Initial speed #4
Target speed #2
1012
1002
Sequence #4 X axis designation
Completion code: continuous
Dwell time #0
1013
0011
Dwell time #0
Acceleration time #1
Deceleration time #1
1014
0403
Deceleration time #1
Initial speed #4
Target speed #3
1015
1003
Sequence #5 X axis designation
Completion code: bank end
Dwell time #0
1016
0011
Dwell time #0
Acceleration time #1
Deceleration time #1
1017
0400
Deceleration time #1
Initial speed #4
Target speed #0
Note
Addresses other than the above should be set to their factory values.
Address
Setting
Contents of setting
1300
0150
Speed #0
150 pps
1301
0300
Speed #1
300 pps
1302
0400
Speed #2
400 pps
1303
0500
Speed #3
500 pps
1304
0000
Speed #4
0 pps
Note
Addresses other than the above should be set to their factory values.
Positioning Sequences
Speeds
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...