263
Appendix F
Using with CS1-series PCs
Observe the following points when using C200HW-NC113/NC213/NC413 PCUs with CS1-series PCs.
Differences in Operating Memory Area and Common Parameter Area Allocations
The beginning words of the operating memory area (n) and common parameter area (m) will differ in the way
shown below.
•
Beginning Word of Operating Memory Area, n
Changes from n = IR 100 (or 400 when unit number
y
A) + (unit number
×
10)
to n = CIO 2000 + (unit number
×
10)
•
Beginning Word of Common Parameter Area, m
Changes from m = DM 1000 + (unit number
×
100)
to m = (unit number
×
100)
Differences in Operating Data Area and Data Transfer Area Designations
When designating the operating data area (using the common parameters) and the data transfer area (from the
operating data area), the following restrictions apply.
Operating Data Area (I to I + 33 max.)
Only the following areas can be set using the common parameters (m, m+1):
•
D00000 to D00999
•
D02600 to D05999
•
E0_00000 to E0_06143
m = (unit number
×
100)
I = Beginning word of operating data area
Area
Address in CS1 CPU
Unit
Designation method using common parameters
(m onwards)
U
Designation of operating
data area (I onwards):
Word m, bits 00 to 15 (Hex)
Beginning address of
operating data area (I):
Word m+1, bits 00 to 15
(4 digits, BCD)
General-purpose DM area
D00000 to D00999
000D Hex
0000 to 0999
p p
D02600 to D05999
2600 to 5999
EM area, bank 0
E0_00000 to E0_06143
000E Hex
0000 to 6143
Note
Only the CPU Unit memory addresses in the above table can be designated.
Summary of Contents for C200HW
Page 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Page 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...