Storage item
Storage details
Md.34 Axis warning No.
When an axis warning is detected, the warning code corresponding to the details of
the warning is stored.
•
The latest warning code is always stored. (When a new axis warning occurs,
the warning code is overwritten.)
•
When " Cd.12 Axis error reset" (axis control data) turns ON, the axis warning
No. is cleared (set to 0).
Md.35 Axis operation status
The axis operation state is stored.
Md.36 Current speed
"
Da.7 Command speed" of positioning data currently execution is stored.
•
When "–1" is set for "
Da.7 Command speed": The command speed of the
previous positioning data is stored.
•
When a value other than "–1" is set for "
Da.7 Command speed": The
command speed of the positioning data currently being executed is stored.
•
When the speed change function is executed : " Cd.16 New speed value" is
stored. (For details of the speed change function, refer to Section 12.5.1.)