6 - 34
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
(3) Control data requiring setting
Set the following data to execute restart.
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3
Cd.13 Restart command
1
Set "1: restarts".
1152 1202
1252
* Refer to section "5.7 List of control data" for details on the setting details.
(4) Starting conditions
The following conditions must be satisfied when restarting. (Assemble the
required conditions into the sequence program as an interlock.)
(1) Operation state
"
Md.35 Axis operation status" is "1: Stopped"
(2) Signal state
Device
Signal name
Signal state
Axis 1 Axis 2 Axis 3
PLC READY signal
ON PLC CPU preparation completed
Y1D
AD75 READY signal
OFF AD75 preparation completed
X0
Axis stop signal
OFF Axis stop signal is OFF
Y13
Y14
Y1C
Start complete signal
OFF Start complete signal is OFF
X1
X2
X3
BUSY signal
OFF BUSY signal is OFF
X4
X5
X6
Error detection signal
OFF There is no error
XA
XB
XC
Interface
signal
M code ON signal
OFF M code ON signal is OFF
XD
XE
XF
Drive unit READY signal ON Drive unit preparation completed
–
Stop signal
OFF Stop signal is OFF
–
Upper limit (FLS)
ON Within limit range
–
External
signal
Lower limit (RLS)
ON Within limit range
–
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...