14 - 26
MELSEC-A
14 TROUBLESHOOTING
Division of
error
Error
code
Error name
Description
Action at occurrence of error
958
JOG deceleration
selection setting
error
The setting range of “JOG deceleration time
selection” in detail parameter 2 is out of the
setting range.
959
Acceleration/dec
eleration
selection setting
error
The setting range of “acceleration/deceleration
process selection” in detail parameter 2 is out
of the setting range.
960
S-curve ratio
setting error
The setting range of the “S-curve ratio” in detail
parameter 2 is out of the setting range.
962
Illegal sudden
stop deceleration
time
The setting range of the “sudden stop
deceleration time” in detail parameter 2 is out
of the setting range.
963
Stop group 1
sudden stop
selection error
The setting range of “stop group 1 sudden stop
selection” in detail parameter 2 is out of the
setting range.
964
Stop group 2
sudden stop
selection error
The setting range of “stop group 2 sudden stop
selection” in detail parameter 2 is out of the
setting range.
965
Stop group 3
sudden stop
selection error
The setting range of “stop group 3 sudden stop
selection” in detail parameter 2 is out of the
setting range.
966
Outside
allowable circular
interpolation error
width range
The setting range of the “allowable circular
interpolation error width range” in detail
parameter 2 is out of the setting range.
967
External start
selection error
The setting range of “external start function
selection” in detail parameter 2 is out of the
setting range.
At start: Failure to start
During operation:
Stopping according to sudden stop
(stopping group 3) setting
(deceleration and stop/sudden
stop) selected in detail parameter 2
(However, deceleration and stop only during
manual pulse generator operation)
971
Path control
mode error
The “near pass mode selection for path control”
setting in detail parameter 2 is out of the setting
range.
980
Zero point return
method error
The setting range of the “zero point return
method” zero point return basic parameter is
out of the setting range.
981
Zero point return
direction error
The setting range of the “zero point return
direction” zero point return basic parameter is
out of the setting range.
Parameter
982
Zero point
address setting
error
The setting range of the “zero point address”
zero point return basic parameter is out of the
setting range.
The AD75 READY signal (X0) is not turned
OFF.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...